Sprinkler system

AUTOMATIC SYSTEM

Sprinkler system

Automatic water protection · building network

A water protection network that activates locally once the temperature threshold is exceeded.

Activation
Thermal element
Design
Hydraulic calculation
Network
Heads + pipe + pump
Application
Retail · warehouse · office

SPRINKLER SYSTEM

Automatic water protection calculated for the site.

A sprinkler network is more than the number of heads. Ceiling height, occupancy, water source, pipe routing and fire load together shape the engineering decision.

Hydraulic calculation, pump station and heads are selected for ceiling height, occupancy and fire class.

Activation
68°C · 79°C
Coverage
Up to 12 m²/head
Environment
Office · Warehouse · Hotel
Sprinkler system

HOW THE SYSTEM IS BUILT

Every part belongs to one protection line.

Hydraulic and operational decisions are clarified before installation.

  • 01

    Head selection

    Head type and layout are selected around the ceiling, risk zone and physical obstructions.

  • 02

    Water supply

    Pumps, reserve capacity and related valves are considered as one system for the project need.

  • 03

    Acceptance points

    Visible installation quality, controls and the handover route for the operations team are defined in advance.

APPLICATION AREAS

Look beyond the building type to the real risk scenario.

The engineering calculation follows the operation and load of each area.

  • 01

    Warehousing and logistics

    Height, racking layout and stored-goods profile are key inputs to the water-network decision.

  • 02

    Office and retail

    Zoning accounts for people flow, ceiling structure and service access.

  • 03

    Hotels and mixed-use buildings

    Different floor uses and scenarios need coordination inside one project framework.

DELIVERY PROCESS

From the floor plan to an operation-ready network.

The project stages keep responsibilities and next checks clear.

  1. 01

    Risk and site review

    Plans, height, use type and existing water infrastructure are reviewed.

  2. 02

    Hydraulic design

    Network routing and project parameters are calculated together.

  3. 03

    Installation and zoning

    Pipes, valves and heads are installed in the approved site sequence.

  4. 04

    Testing and handover

    Acceptance steps and the follow-up service route are recorded for the facility team.

FREQUENTLY ASKED QUESTIONS

Let’s determine the right scope for your facility.

Is a sprinkler system installed the same way in every facility?

No. Ceiling height, water infrastructure, use type, fire load and architectural constraints change the project.

Can sprinklers be added to an existing building?

Yes, but routing, water supply, ceiling construction and operating conditions must first be reviewed on site. A retrofit may require a phased plan.

When is the service plan defined?

At handover, the service route is set around the approved configuration, operating conditions and applicable requirements.